The solutions offered by Energy Design & Consulting covers the entire range of elements involved in the deployment of SCADA & ITC: Dedicated software platforms, intelligent data processing equipment, field instrumentation for data acquisition, diverse and secure communications solutions.

SCADA systems are based on open architecture, redundancy and multiple configuration possibilities. SCADA Solutions develops along with the process and can be changed at any time as needed.

Energy Design & Consulting may develop both the necessary documentation, starting with the design, specifications and so on in order to provide a turnkey implementation of SCADA & ITC.


 

SCADA

References:

SCADA system for System Control & Dispatching Company for monitoring and control of photovoltaic and wind headquarters and integration with National Power Control.
Client: System Control & Dispatching Company

EDC has implemented SCADA dispatcher for System Control & Dispatching Company for more than 20 plants of renewable electricity production, photovoltaic and wind, with an installed cumulative capacity of 300MW+ , with the responsibility of implementing related components:

  • dispatch design for System Control & Dispatching Company
  • SCADA System Implementation
  • Communication gateway integration with National Power Control
  • RTU systems integration and maintenance of the photovoltaic Power Plants and wind farms

SCADA system for reactive power compensation and marks of active and reactive power of the wind farm of 10MW at Topliceni and 10MW at Grebanu
Client: M & M 2008 Wind Center

EDC has provided and implemented reactive power compensation systems and control of active and reactive power marks in two wind farms with an installed capacity of 10 MW by implementing the following elements:

  • Designing compensation system and SCADA system
  • Delivery and implementation of equipment and SCADA system
  • System integration with SCADA at System Control & Dispatching Company and Nordex turbine control
  • Integration and maintenance of RTU systems for wind power plant
    • SCADA system for monitoring, control and development of active and reactive power marks for 6.4MW photovoltaic power plant at Ghelari
      Client: Corvin Fotovoltaic

      EDC has suplied and implemented the monitoring systems for orientation of photovoltaic panels, monitoring and control systems for inverters and transformer substations, reactive power compensation systems and control of active and reactive power marks by implementing the following elements:

      • Designing compensation system and SCADA system
      • Delivery and implementation of equipment and SCADA system
      • System integration with SCADA at System Control & Dispatching Company and inverter control systems
      • Integration and maintenance of RTU systems for photovoltaic power plant

       

      ITC

      References:

      Rehabilitation with investment component “Remote Countering system of wholesale electricity market” (phases SF, CS)
      Client: Transelectrica

      EDC has conducted feasibility study and specifications of remote countering system for the wholesale market.

      Communication system for dispatch at System Control & Dispatching Company connecting photovoltaic and wind power plants and National Energetic Dispatch.
      Client: System Control & Dispatching Company

      EDC has implemented communications and IP security system for more than 20 plants of renewable electricity production, photovoltaic and wind, the redundant communication with National Energetic Dispatch, voice communication system with regional dispatches, having the responsibility for implementing of the following related components:

      • Design of communications system
      • Implementation of the communication gateway with ModbusTCP industrial protocols, IEC 104, IEC 101 and IEC61850
      • Implementation of the communication gateway with DEN
      • VPN implementation for photovoltaic and wind plants
      • Integration and maintenance of communication systems within photovoltaic and wind plants and within DLC at System Control & Dispatching Company

      Communication system for wind plants of 10 MW at Topliceni and Grebanu with the 110kV / 20kV station at Costieni and System Control & Dispatching Company
      Client: M & M 2008 and Eolian Center

      EDC has implemented communications and IP security system for the wind power plants of 10 MW at Topliceni and Grebanu with 110kV / 20kV station at Costieni and System Control & Dispatching Company, having the responsibility for implementing these components:

      • Design of communications system having 6 knots in optical fiber ring
      • System delivery and implementation by using MOXA equipments
      • Implementation of the communication gateway with ModbusTCP industrial protocols, IEC 104, IEC 101 and IEC61850
      • VPN implementation for power plants and dispatcher station Costieni
      • Integration and maintenance of communications systems within wind power plants

      Communications system for 6.4 MW photovoltaic plant at Ghelari (Corvin Fotovoltaic) with 110kV / 20kV station at Teliuc and System Control & Dispatching Company
      Client: Corvin Fotovoltaic

      EDC has implemented IP communication and security system between 6.4 MW photovoltaic plant at Ghelari (Corvin Fotovoltaic) and the 110kV / 20kV station at Teliuc and DLC, having the responsibility of implementing these components:

      • Design of communications system having 8 nodes in optical fiber ring
      • System delivery and implementation by using MOXA equipments
      • Implementation of the communication gateway with ModbusTCP industrial protocols, IEC 104, IEC 101 and IEC61850
      • VPN implementation for power plants and Teliuc station and DLC
      • Integration and maintenance of communications systems within wind power plants

       

      SMART GRID

      References:

      Study on strategy development for implementing the concept of Smart Grid in Transelectrica SA – phase II
      Client: Transelectrica

      EDC in partnership with Nova Industrial has provided this study with responsibility for drafting the following:

      • Identifying SmartGrid network architecture
      • Methods for measuring energy
      • Renewable energy forecasting methods
      • Integration and dispatching of renewable energy sources
      • Information needed for centralized dispatch of renewable energy
      • Necessary conditions for accomplishing the SmartCity concept

      Feasibility study for pilot project of SmartGrid – development of SmartGrid solutions of using renewable energy and provision storage for power backup solutions of internal services – 400/220/110 kV station at Brazi Vest
      Client: Transelectrica

      EDC has developed this study addressing these items:

      • Identifying solutions for renewable power resources
      • Identify storage solutions for renewable energy
      • Command and control system architecture of local microgrid
      • Establish criteria to generalize the project
      • Choosing the best solutions that are in terms of economic indicators
      • Proposing directions of development and implementation